background image

 1

 1

Refer to protection notice ISO 16016

07. Nov. 2008

1

2010 Eaton Corporation. All rights reserved.

easyControl series EC4P

Powerful Compact PLC

background image

 2

 2

Refer to protection notice ISO 16016

07. Nov. 2008

2

2010 Eaton Corporation. All rights reserved.

easyControl EC4P

Powerful compact PLC

background image

 3

 3

Refer to protection notice ISO 16016

07. Nov. 2008

3

2010 Eaton Corporation. All rights reserved.

easyControl EC4P 

Contents

 System Overview

 Product Features

 Technical Data

 Product Range

 Programming Software 

Environment

 Communication Features

 Topology

 Characteristics and Benefits

background image

 4

 4

Refer to protection notice ISO 16016

07. Nov. 2008

4

2010 Eaton Corporation. All rights reserved.

easyRelay

easyControl

easy expansion 

EC4P

MFD-80

easyHMI

easySoft

easySoft-CoDeSys

Easy 500Easy 700 Easy 800

MFD-CP8

I/O

communication

XControl

XC100

XC200

XIOC

easyControl EC4P

System Overview

background image

 5

 5

Refer to protection notice ISO 16016

07. Nov. 2008

5

2010 Eaton Corporation. All rights reserved.

easyControl EC4P

 

Continue easy success story

background image

 6

 6

Refer to protection notice ISO 16016

07. Nov. 2008

6

2010 Eaton Corporation. All rights reserved.

easyControl EC4P

 

Product Features

Powerful compact automation device in easy800 format

Use of easy range expansion units (easyLink)

Programming software according to IEC 61131-3 
(CoDeSys inside)

1 Multi Media Card for application, operation system and 
data

Units with or without display

Display of status and diagnostics

Use of display as a text display in the application

CANopen and/or easyNet onboard

Units with additional Ethernet interface

2 x RS232 on board

background image

 7

 7

Refer to protection notice ISO 16016

07. Nov. 2008

7

2010 Eaton Corporation. All rights reserved.

12 Input

24 V DC

2 Counter

50 KHz

16 Bit

1 Counter

50 KHz

32 Bit

4 Interrupt

3 kHz

4 Analog I

10 Bit

0 – 10 V

8 Output

24 V DC

6 Output

Relais 8A

or

optional

optional

alternative

easyLink

expansion

1 Encoder

32 Bit

40 KHz

1 Analog Q

10 Bit

0 – 10 V

or

or

Etherne

t

optional

easyControl EC4P 

Technical data – I/O

background image

 8

 8

Refer to protection notice ISO 16016

07. Nov. 2008

8

2010 Eaton Corporation. All rights reserved.

Program

memory

256 kB SRAM

Data

memory

224 kByte

CPU

< 0,3 ms 

1000 instruc.

Input-

data

4096 Byte

%I

Output-

data

4096 Byte

%Q

Marker

16 kByte

%M

Supply

24 V DC

Var Retain

8 kByte

Text display

Parameter

Text: ABC...
Param.1:
Param.2:
Text: ...XYZ

Temperature

-25 ... +55°C

Memory module

MMC 64MB

easyControl EC4P 

Technical data – CPU

background image

 9

 9

Refer to protection notice ISO 16016

07. Nov. 2008

9

2010 Eaton Corporation. All rights reserved.

easyControl EC4P 

Technical data EC4P vs. easy800

EC4P

easy800

Quantity of local I/O incl. 
Expansion units

MFD CP4 as Remote display

easyNet



CANopen



-

Frequency of Counter / 
Encoder

50KHz / 40 KHz

5KHz / 3KHz

Memory, Speed

++

Memory module

++

Serial interfaces

Can be used as 

application interface

Programming

IEC-6-1131-3

Ladder Logic

background image

 10

 10

Refer to protection notice ISO 16016

07. Nov. 2008

10

2010 Eaton Corporation. All rights reserved.

E

C

4

P

-2

2

1

-M

T

X

D

1

Easy

Control

4 = 45 mm Range
P = Programmable

2 = Performance Range

1 = w/o Ethernet (2 = Ethernet )

M = Inputs Mixed (Digital , Analog optional)

T = Outputs Transistor / R = Relay

X = w/o Analogue Q (A = Analogue Q )

X = w/o Display / D = Display

1 = Version-Code

2 = DC-Supplied

easyControl EC4P

 

Technical data – key to type

background image

 11

 11

Refer to protection notice ISO 16016

07. Nov. 2008

11

2010 Eaton Corporation. All rights reserved.

8/12 Input

24 V DC

8 Output

24 V DC

6 Output

Relais 8A

8/12 Input

24 V DC

CANopen

easyNet

CANopen

easyNet

EC4P-221-MTXD1 EC4P-221-MTXX1

EC4P-221-MRXD1EC4P-221-MRXX1

4 Analog I

10 bit

0 – 10 V

4 Analog I

10 bit

0 – 10 V

easyControl EC4P

Product Range - devices with analogue inputs

background image

 12

 12

Refer to protection notice ISO 16016

07. Nov. 2008

12

2010 Eaton Corporation. All rights reserved.

8/12 Input

24 V DC

8 Output

24 V DC

6 Output

Relais 8A

8/12 Input

24 V DC

CANopen

easyNet

CANopen

easyNet

EC4P-221-MTAD1EC4P-221-MTAX1

EC4P-221-MRAD1EC4P-221-MRAX1

4 Analog I

10 bit

0 – 10 V

4 Analog I

10 bit

0 – 10 V

easyControl EC4P

Product Range - devices with additional analogue output

background image

 13

 13

Refer to protection notice ISO 16016

07. Nov. 2008

13

2010 Eaton Corporation. All rights reserved.

8/12 Input

24 V DC

8 Output

24 V DC

6 Output

Relais 8A

8/12 Input

24 V DC

CANopen

easyNet

CANopen

easyNet

EC4P-221-MTXD1EC4P-221-MTXX1

EC4P-221-MRXD1EC4P-221-MRXX1

4 Analog I

10 bit

0 – 10 V

4 Analog I

10 bit

0 – 10 V

Etherne

t

Etherne

t

easyControl EC4P

Product Range - devices with analogue inputs and 
Ethernet

background image

 14

 14

Refer to protection notice ISO 16016

07. Nov. 2008

14

2010 Eaton Corporation. All rights reserved.

8/12 Input

24 V DC

8 Output

24 V DC

6 Output

Relais 8A

8/12 Input

24 V DC

CANopen

easyNet

CANopen

easyNet

EC4P-221-MTAD1EC4P-221-MTAX1

EC4P-221-MRAD1EC4P-221-MRAX1

4 Analog I

10 bit

0 – 10 V

4 Analog I

10 bit

0 – 10 V

1 Analog Q

10 bit

0 – 10 V

1 Analog Q

10 bit

0 – 10 V

Etherne

t

Etherne

t

easyControl EC4P

Product Range - devices with add. analogue output and 
Ethernet

background image

 15

 15

Refer to protection notice ISO 16016

07. Nov. 2008

15

2010 Eaton Corporation. All rights reserved.

IS / AWL

LD     A

ST     B

LD / KOP

FUP

SC / AS

ST

IF A > B

THEN C

ELSE D

CFC

  all programming languages acc. to IEC 

61131-3

  simulation 

  unlimited online change

  Incl. and compatible to 

XC100,121,201,202, MFD4

  integrated visualization

easyControl EC4P

Xsoft-CoDeSys - Programming Software according to 
IEC61131-3

background image

 16

 16

Refer to protection notice ISO 16016

07. Nov. 2008

16

2010 Eaton Corporation. All rights reserved.

Prog

4. CAN 

1. RS 232

2. 

Ethernet*

3. RS 232

EU4A-RJ45-CAB1

1.

Use RS232 programming 

cable (EU4A-RJ45-CAB1)

2.

Use USB/RS232 

programming cable (EU4A-

USB-CAB)

3.

Ethernet on top with EC4P 

222* devices

4.

Routing through EC4P and 

CANopen network to 

remote plc (EC4P, XC100, 

200)

EU4A-USB-CAB

easyControl EC4P

Communication access

background image

 17

 17

Refer to protection notice ISO 16016

07. Nov. 2008

17

2010 Eaton Corporation. All rights reserved.

CANopen

easyNet

AS-Interface

Slave

Profibus-DP

Slave

DeviceNet

Slave

CANopen

Slave

optional

RS 232

easyCom

RS 232

Sucom-A,

Modbus

RS 232 /

 Ethernet

OPC

easyControl EC4P

Communication options - Overview

background image

 18

 18

Refer to protection notice ISO 16016

07. Nov. 2008

18

2010 Eaton Corporation. All rights reserved.

AS-I

Profibus DP

CANopen

DeviceNet

2Q R

6Q R

6Q R

8Q T

12I DC

12I DC

12I AC

easyLink

Extensions

easyControl EC4P

 

Topology – easyLink - Extensions

background image

 19

 19

Refer to protection notice ISO 16016

07. Nov. 2008

19

2010 Eaton Corporation. All rights reserved.

XC201/202

Max. 8 devices

easy800

MFD-Titan

EC4P

Smartwire XStart

easyControl EC4P

 

Topology – easyNet

easyNet

MFD4

background image

 20

 20

Refer to protection notice ISO 16016

07. Nov. 2008

20

2010 Eaton Corporation. All rights reserved.

EC4

P

         

XV

XC100      

XC201/202

drives                        XStart

Remote 

I/O

easyControl EC4P

 

Topology – CANopen

CANopen

background image

 21

 21

Refer to protection notice ISO 16016

07. Nov. 2008

21

2010 Eaton Corporation. All rights reserved.

Programming Software

SW-XSOFT-CODESYS-2-S (single user licence)

SW-XSOFT-CODESYS-2-M (multi user licence)

Programming Cable 

(for easyControl and XC)

 

EU4A-RJ45-CAB1

Memory Card (RS-MMC) with Adaptor

EU4A-MEM-CARD1

Programming Cable 

(for easy800 and easyControl)

 

EASY-800-USB-CAB

easyControl EC4P

Range of accessories

background image

 22

 22

Refer to protection notice ISO 16016

07. Nov. 2008

22

2010 Eaton Corporation. All rights reserved.

 Clear and easy to use 

automation system 
(easyRelay, easyControl) 

Saves invest in hardware and 
software

 Many I/O features already 

onboard

Many devices enable cost 
optimized automation solution 

 Networking via easyNet and 

CANopen

Extension with standard CANopen 
or easyNet remote stations 

 Integrated text display for text 

messages in an application or 
MFD80 as remote display 

Easy machine operating or 
diagnostics from your integrated 
display; comfortable (IP65, Brand)

easyControl EC4P 

Characteristics and Benefits I

background image

 23

 23

Refer to protection notice ISO 16016

07. Nov. 2008

23

2010 Eaton Corporation. All rights reserved.

 Short cycle time

 Compact Housing

 Standard memory card 

(read / write with normal 
computer)

 Well known and very 

comfortable programming 
environment

 Libraries for control loop 

and motion control 
application

Realization of fast machine cycles

Saves space in cabinet

Logging huge amount of data 
over large period of time

Effective development thanks to 
the very easy to handle and very 
powerful programming software 

Tested function blocks reduce 
user software development

easyControl EC4P

 

Characteristics and Benefits II

background image

 24

 24

Refer to protection notice ISO 16016

07. Nov. 2008

24

2010 Eaton Corporation. All rights reserved.


Document Outline