Product-Feature PLC(1)

XC-CPU121-2C256K

Overview: 

 compact din rail PLC 90*100* 50 mm 

(B*H*T)

 2 CAN- and 2 serial interfaces

 Large program and data memory 

 MMC Card for recipe and software update

 Real time clock

 Extensible via I/O board and standard XIOC 

signal boards

background image

 3

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XC-CPU121

Product-Feature PLC(2)

XC-CPU121-2C256K

PLC-Data

 256KB/224KB Program- / Data memory 

 16KB Marker, 8KB Retaindaten

 Internal flash memory for Boot project 

 Update from Operating system and 

application via  MMC

 Cycle time  < 0,3ms / K

 1 cyclic Task, 1 Timer Interrupt Task

 6 I/O Interrupt Tasks

background image

 4

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XC-CPU121-2C256K

XC-CPU121

Product-Feature PLC(3)

Serial Communication 
COM1, COM2 

 COM1: RS232 (max. 57,6KB) 

for programming  / application, 
RJ45 socket

 COM2: RS232/ RS485 (max. 

57,6KB) for application, 
removable 6 pin tension clamp 
(like XC100 CAN)

 All known communication 

libraries can be used SUCOM-A, 
Modbus Master, Slave, SMS etc

background image

 5

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

CAN 1 interface

CAN 2 interface

XC-CPU121

Product-Feature PLC(4)

Fieldbus communication CAN1, 
CAN2

 CAN1, CAN2: Fieldbus interface acc. CIA DS310 

V4,0. 

 Can be used as NMT master or CAN-device 

 Remote programming (XC100, XC121) via CAN1 

or CAN2

 Max. Baud rate 500 KB

 Switches for bus termination on board

 One Node-ID address can be set via address 

switch on the PLC

background image

 6

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XC-CPU121-2C256K

More ..

 Operating switch (Start, Stop)

 Reset push button

 Real time clock with Super CAP ( ~2 weeks 

buffering)

 No battery needed for retentive data (Flash 

memory)

XC-CPU121

Product-Feature PLC(5)

background image

 7

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XC-IO121

Product-Feature I/O (1)

XIO-EXT-1

I/O Daten

 Digital I/O

10 digital Inputs 24V DC (incl. 6 Interrupt 

Inputs) 

 8 independent configurable IO

 DI  24VDC,

 DO 24VDC, 0,5A, short circuit proof

 Analogue I/O

Analogue Inputs

2 * 0-10V

2* 0-20mA

2*PT100 (-200° - + 200°)

10 Bit , 0,5%

Analogue Output

2 * 0-10V 

12 Bit, 0,5% error

 Interface fore more XIOC signal boards

background image

 8

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XC-CPU121

Desired Customers / application advantage 

XC-CPU121-2C256K

 Special designed for cost sensitive OEM markets 

(no optical isolated I/O, or field bus, no I/O LEDs)

Replacement of OEMs own development

 Flexible communication interfaces cover a lot of 

application

232 und 485 needs

 Modbus, SUCOM, SMS, other serial protocol

2 CANopen, CAN-Device

Quick setup features

Plug and play. Node ID can be set by 

hardware (identical application devices can be 
configured at the machine)  

Update of application program via MMC

High Value Modules (Profibus etc. ) can be added 

to the base configuration

background image

 9

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XC-CPU121

System-Feature (1) PLC with fieldbus I/O  

Modbus 

232/485

COM2

COM1

CAN 1

 PLC with remote CANopen I/O 

 Additional serial communication to 

HMI, MODEM, or other serial device

 Serial communication to Modbus 

clients

background image

 10

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XC-CPU121

System-Feature (2) Stand alone PLC with I/O Board

 10 Digital 

Inputs

8 Digital In-

Outputs

6 analogue 

Inputs

analogue 

Outputs

 2 * 0-10V

 2 * 0-

20mA

2* 

PT100

2* 0-10V

Interrupt

PLC with flexible I/O

18 I/O (max. 18 Input max. 8 

Output)

 6 Interrupt Inputs

 Different analogue I/O (0-10V, 0-

20mA, PT100)

background image

 11

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XC-CPU121

System-Feature (3) PLC with I/O Board + XIOC Extension

 10 Digital 

Inputs

8 Digital In-

Outputs

6 analogue 

Inputs

analogue 

Outputs

 2 * 0-10V

 2 * 0-

20mA

2* 

PT100

2* 0-10V

Additional XIOC Signal modules can 

be used

All modules  (not DP Master, 

Slave)

Enhanced Counter functionalities

Max. 15 modules

background image

 12

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XC-CPU121

System-Feature (4) CAN networking 

CAN 1

Baudrate 1

CAN 2

Baudrate 2

CAN 2

Baudrate 2

CAN 1

Baudrate 1

 Gateway between different CAN 

Networks

 Adaptation of different Baud rates

 Remote data pre-processing

 Remote independent PLC

background image

 13

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XC-CPU121

Summary

XC-CPU121-

2C256K

Advantages

 Very compact housing

 Multiple communication interfaces

 Extension with I/O Board

 Additional XIOC signal modules possible

 Interesting price 

 Powerful ECP Programming Environment + add. 

libraries

background image

 14

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XN-ECO

Technical Data XC-CPU121-2C256

background image

 15

Observe protective note ISO 16016

28.05.21

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

S

ch

u

tz

ve

rm

e

rk

 IS

O

 1

6

0

1

6

 b

e

a

ch

te

n

XN-ECO

Technical  Data XIO-EXT-1


Document Outline