CZĘŚĆ PRAKTYCZNA
Celem wykonywanego ćwiczenia jest poszerzenie amperomierza i woltomierza
Iw[mA] |
160 |
200 |
250 |
140 |
120 |
230 |
280 |
220 |
180 |
170 |
Ib[mA] |
80 |
100 |
124 |
70 |
60 |
115 |
140 |
110 |
90 |
86 |
Uw[V] |
60 |
50 |
90 |
30 |
15 |
22 |
66 |
81 |
57 |
39 |
Ub[V] |
20 |
25 |
30 |
10 |
5 |
8 |
22 |
27 |
19 |
13 |
Dla amperomierz Ra = 4,7 n = 2 więc Rb = 4,7
Dla woltomierza Rv = 121 n = 3 więc R = 242
W celu wykonania obliczeń zastosuje metodę regresji liniowej
Dla woltomierza
Lp. |
xi |
yi |
xiyi |
xi |
yi |
1. |
20 |
60 |
1200 |
400 |
3600 |
2. |
25 |
50 |
1250 |
625 |
2500 |
3. |
30 |
90 |
2700 |
900 |
8100 |
4. |
10 |
30 |
300 |
100 |
900 |
5. |
5 |
15 |
75 |
25 |
225 |
6. |
8 |
22 |
176 |
64 |
484 |
7. |
22 |
66 |
1452 |
484 |
4356 |
8. |
27 |
81 |
2187 |
729 |
6561 |
9. |
19 |
57 |
1083 |
361 |
3249 |
10. |
13 |
39 |
507 |
169 |
1521 |
|
179 |
510 |
10930 |
3857 |
31496 |
(xi ) = 32041
Korzystam ze wzoru a = (yixi - nxiyi)/((xi) - nxi) a = 2,7584
b = (yi - axi)/n b = 1,6234 V
Sa = n[yi - axi - byi]/(n-2)[nxi - (xi) ] Sa = 0,3149
Sb = (1/n)*Sa*xi Sb = 3,1850
Dla amperomierza
Lp. |
xi |
yi |
xiyi |
xi |
yi |
1. |
80 |
160 |
12800 |
6400 |
25600 |
2. |
100 |
200 |
20000 |
10000 |
40000 |
3. |
124 |
250 |
31000 |
15376 |
62500 |
4. |
70 |
140 |
9800 |
4900 |
19600 |
5. |
60 |
120 |
7200 |
3600 |
14400 |
6. |
115 |
230 |
26450 |
13225 |
52900 |
7. |
140 |
280 |
39200 |
19600 |
78400 |
8. |
110 |
220 |
24200 |
12100 |
48400 |
9. |
90 |
180 |
16200 |
8100 |
32400 |
10. |
86 |
170 |
14620 |
7396 |
28900 |
|
975 |
1950 |
201470 |
100697 |
403100 |
(xi) = 950625
Korzystam ze wzoru a = (yixi - nxiyi)/((xi) - nxi) a = 2,0134
b = (yi - axi)/n b = -1,3151
Sa = n[yi - axi - byi]/(n-2)[nxi - (xi) ] Sa = 0,0124
Sb = (1/n)*Sa*xi Sb = 1,2469
WNIOSKI
Założony cel został osiągnięty. Na niedokładność pomiaru mogło wpłynąć wiele czynników tj.
wada urządzeń wykorzystywanych podczas przeprowadzania doświadczenia
niedokładny odczyt wartości z mierników