background image

 

 

background image

 

 

AMERICAN COAL MINE 

SAFETY

Methane Regulations and Other 

Issues

By

Jeff Watkins, President

Hill & Associates, Inc.

222 Severn Ave.

Annapolis, MD USA

www.hillandassoc.com

background image

 

 

background image

 

 

background image

 

 

HISTORY OF MINE SAFETY AND HEALTH LEGISLATION

1891 LAW

Limited Jurisdiction – only applied in US Territories.
Established minimum ventilation requirements in underground coal mines.
Prohibited operators from employing children under 12 years of age.

1900–1910 : COAL MINE FATALITIES EXCEEDED 2,000 ANNUALLY

1910 : BUREAU OF MINES ESTABLISHED (BOM)

Charged with responsibility to conduct research and to reduce accidents in 
the coal mining industry.
No inspection authority.

1941 : BUREAU OF MINES GIVEN INSPECTION AUTHORITY

1947 : US CONGRESS AUTHORIZED THE FORMULATION OF THE FIRST 

CODE OF FEDERAL REGULATIONS FOR MINE SAFETY

background image

 

 

1952 : FEDERAL COAL MINE SAFETY ACT OF 1952

Provided for annual inspection in certain underground coal mines.
Gave BOM limited enforcement authority including:

power to issue violation notices
issue imminent danger withdrawal orders

Authorized assessment of civil penalties for:

noncompliance with withdrawal orders
refusing to give inspectors access to mine property

No provision was made for monetary penalties for noncompliance with 
safety provisions

1966 : MINE SAFETY ACT OF 1952 EXTENDED TO ALL UNDERGROUND 

COAL MINES

1968 : NOVEMVER 20, 1968 AN EXPLOSION AT THE CONSOL #9 MINE 

AT FARMINGTON, WEST VIRGINIA RESULTS IN 78 FATALITIES

 

background image

 

 

1969 : FEDERAL COAL MINE HEALTH AND SAFETY ACT OF 1969

Included surface as well as underground mines.
Required two annual inspections of all surface mines and four annual 

inspections of underground mines.
Dramatically increased federal enforcement powers in coal mines
Required monetary penalties for all violations.
Established criminal penalties for knowing and willful violations.
Safety standard for all coal mines were strengthened and health standards 

were adopted.
Included specific procedures for the development of improved mandatory 

health and safety standards.
Provided compensation for miners who were totally and permanently 

disabled by black lung.

1973 : MINING ENFORCEMENT AND SAFETY ADMINISTRATION (MESA) 

CREATED
Assumed the safety and health enforcement functions formerly carried out 

by the BOM 

1977 : FEDERAL MINE SAFETY AND HEALTH ACT OF 1977

Consolidated all federal health and safety laws (coal and non-coal) under 

single statutory scheme.
Expanded rights of miners and enhanced protection of miners from 

retaliation for exercising rights.
Transferred responsibility to Mine Safety and Health Administration (MSHA) 

under Department of Labor.
Established Federal Mine Safety and Health Review Commission to provide 

independent review of the majority ot MSHA’s enforcement actions.

background image

 

 

METHANE EXAMINATIONS

METHANE MONITORS SHALL BE APPROVED BY MSHA, MAINTAINED IN 

PERMISSIBLE AND PROPER OPERATING CONDITION, AND 

CALIBRATED WITH A KNOWN METHANE-AIR MIXTURE AT LEAST 

ONCE EVERY 31 DAYS

PRESHIFT EXAMINATION

Within 3 hours preceding the beginning of any 8-hour interval during which 

any person is scheduled to work or travel underground.

ON-SHIFT EXAMINATION

At least once per shift in any area where mechanized mining equipment is 

being installed or removed.
Along each belt conveyor haulageway where a belt is being operated during 

each shift that coal is being produced.
At the start of each shift at each working place before electrically operated 

equipment is energized.
Immediately before equipment is energized, taken into, or operated in a 

working place.
Intervals of not more than 20 minutes, unless more frequent examination is 

required by the approved ventilation plan.

METHANE MONITORS ON FACE EQUIPMENT

MSHA approved methane monitors shall be installed on all face cutting 

machines, continuous miners, longwall face equipment, loading machines, 

and other mechanized equipment used to extract or load coal within the 

working place

background image

 

 

ACTIONS FOR EXCESSIVE METHANE

WORKING PLACES AND INTAKE AIR COURSES

Over 1.0%

Electrically powered equipment will be deenergized and other 

mechanical 

equipment shut off

Adjustments will be made to the ventilation system to reduce the 

methane 

concentration to less than 1.0%

No other work will be permitted until the methane concentration is 

less than 

1.0%

Over 1.5%

Everyone except those required to reduce the methane content of the 

air will 

be withdrawn from the effected area

Electrically powered equipment in the affected area will be 

disconnected at the 

power source

background image

 

 

METHANE MONITORS ON FACE EQUIPMENT

Over 1.0%

A warning signal will be given.
The warning signal will be visible to a person who can deenergize 

electric 

equipment of shut down diesel-powered equipment on which 

the monitor is mounted.

The monitor will automatically deenergixe electrical equipment or shut 
down diesel-powered equipment on which it is mounted when:

The methane concentration at any methane monitor reaches 2.0%.
The monitor is not operating properly.

background image

 

 

VENTILATION/AIR QUANTITY

CONTINUOUS MINER/CONVENTIONAL SECTIONS

At least 3,000 CFM will reach each working face where coal is being cut, 

mined, drilled for blasting or loaded.
At least 9,000 CFM will reach the last open crosscut on each working 

section.
Greater quantities of air may be required by the approved ventilation plan.

LONGWALL SECTIONS

At least 30,000 CFM shall reach the working face of each longwall, unless 

the operator demonstrates that a lesser air quantity will maintain continual 

compliance with applicable methane and respirable dust standards, lesser 

quantities will be specified in the approved ventilation plan.
Greater quantities of air may be required by the approved ventilation plan .

background image

 

 

3 Types of Monitors

• Catalytic Bead – work best when ambient 

methane level is 0%, otherwise catalyst 

will deteriorate, these are least expensive

• Thermal Conductivity- affected by other 

gases besides methane, can be unreliable

• Infra-red – these are the most reliable and 

most expensive

background image

 

 

Two Major Suppliers

• Conspec
• MSA


Document Outline