Czas opróżniania zbiornika między dowolnymi poziomami:

Obliczenia:

t0=F/( μ*f0)*√(2/g)*(√h -√h1)

ε=(t0-trz)/t0*100

t01=0.113/(0.621*3.42*10-5)*√(2/9.81)*(√0.47-√0.44)=53.43[s]

ε1=(53.43-55)/ 53.43*100=2.938[%]

t02=0.113/(0.621*3.42*10-5)*√(2/9.81)*(√0.42-√0.4)=37.52[s]

ε2=(37.52-40)/ 37.52*100=6.61[%]

t02=0.113/(0.621*3.42*10-5)*√(2/9.81)*(√0.38-√0.35)=59.65[s]

ε3=(59.65-63)/ 59.65*100=5.61[%]

Tabela pomiarów i wyników:

Wnioski:

Na podstawie błędu względnego (ε) można wnioskować , że pomiar czasu wypływu cieczy nie należy do dokładnych. Winą za taki stan rzeczy obarczyć można :

Wielkości mierzone

Wielkości obliczone

Lp.

F

[m2]

f0

[m2]

μ

h

[mm]

h1

[mm]

trz

[s]

t0

[s]

ε

[%]

1

2

3

0.113

3.42*10-5

0.621

470

420

380

440

400

350

55

40

63

53.43

37.52

59.65

2.938

6.61

5.61