background image

 

BKJ2 MODEL 

 

MARINE MASTER-SLAVE CLOCK 

 

DIRECTION 

 

 

 

 

 

 

 

 

 

 

 

 

YANTAI HOROLOGY RESEARCH INSTITUTE 

SHANDONG 

 

 

 

 

 

 

background image

 

CONTENT

 

1

SUMMARIZATION ..................................................................................... 9 

2

MASTER TECHONOLOGIC PARAMETER ............................................. 10 

3

WORK ELEMENT .................................................................................... 10 

4

PANEL INTRODUCTION ......................................................................... 12 

5

METHOD OF FIXING, SPAN AND ADJUSTING ...................................... 12 

6

OPERATION ............................................................................................ 13 

7

OPERATION OF KEY AND SWITCH....................................................... 13 

8

ITEMS AND METHOD IN NATURAL MAINTENANCE ............................ 14 

9

REQUST IN TRANSPORTATION AND STORAGE ................................. 14 

10

REGARDABLE ITEM ............................................................................. 14 

 

 

background image

 

 

1

SUMMARIZATION 

BKJ2  MODEL  MARINE  MASTER-SLAVE  CLOCK  produced  in  YANTAI  HOROLOGY 

RESEARCH  INSTITUTE  SHANDONG  specially  suit  for  large  ship,  as  one  time  service  system.     

This system consists of one master and more than ten slave clocks, which are connected by signal 

cables and power cables. It provides the local time and Greenwich Mean Time (or any desired time) 

in parallel. 

This  system  consists  of  a  master  clock  and  slave  clocks.  Master  clock  can  accept  standard 

time signal that comes from standard time accepted and managed units, check it’s precision, check 

the slave clocks at the same time. 

The equipments of this system are controlled by a single piece micro-processor, automatically 

and operated easily. 

Standard  time  accepting  units  provide  exact  time  signal  to  time  system,  transmit  to  master 

clock through RS422, adjust the precision of master clock, then keep the systems running without 

error. 

In the master clock, its central unit (a micro-processor) and many VLSIC chips form the control 

unit. It is easy to operate and able to adjust all slave clockwise or counter clockwise, with the high 

reliability, it can work at different conditions. A master clock can display by finger and LED method 

and realize all functions through adjusting keyboard. 

The  mater  clock  can  accept  standard  time  signal,  adjust  it’s  precision,  keep  running  without 

error. It can transmit signal to slave clocks, adjust them. Slave clocks can run independently. For 

special movements, which have feedback function, when communication with the master clock is 

ok, the slave clock contrast information to which come from the master clock, run after the master 

clock automatically, keep running in parallel. If not connected with the master clock, you adjust time 

through  keyboard.  It  is  a  checked  not  absolute  directed  relation  between  slave  clocks  and  the 

master click. 

In the power supply of master clock, a AC power detecting circuit is designed, when AC failure 

is  detected,  the  circuit  drives  one  relay  to  switch  over  from  AC  power  supply  to  DC  24V  power 

supply automatically. After AC power recovery, it switches over from DC 24V to AC power supply 

automatically. 

background image

 

10 

2

MASTER TECHONOLOGIC PARAMETER 

1.    mater clock frequency stabilization:      1

×

10

-7 

2.    slave clock frequency stabilization:      1

×

10

-6 

3.    work time: work continually 

4.    master clock work voltage

AC220V

±

10%      50/60Hz

±

5%   

                                                      DC24V

±

25%      Electrical wires are insulated. 

            work electrical current:    0.5A 

5.    slave clock work voltage:      24V 

work electrical current:          about 30mA 

6.    transmitting distance 

300 meter 

3

WORK ELEMENT 

FIGURE 1. SHOWS THE WIRE-DRAWING OF SYSTEM CONSTITUTION   

 

 

 

 

 

 

FIGURE 1      SYSTEM CONSTITUTION   

1.    MASTER CLOCK (FIGURE 2. SHOWS IT) 

Controlled  by  89C51  single  chip,  the  master  clock  memory  data,  operate  coding,  produce 

pulse-signal, transmit to slave clocks through RS422 interface, check slave clocks. At the same 

time, master clock accepts standard time from standard time accept units and check the precision 

itself. 

STANDARD TIME ACCEPT UNIT 

MATER CLOCK 

SLAVR CLOCK 

 

background image

 

11 

high stabilization 
crustal unit

interface

CPU

interface

export interface

slave clock

slave clock

logger

logger

power

standard time

 accept unit interface

 

FIGURE 2      MASTER CLOCK CONSTITUTION

 

2.    SLAVE CLOCK 

 

 

 

 

 

 

 

 

 

FIGURE 3    SLAVE ELEMENT 

 

Slave clocks rely on quartz crystal oscillator in itself, through RS422 interface, connect with 

cable of master clock directly. Accepting standard time signal from master clock, slave clocks check 

their precision, clear up the error automatically, display the uniform time. When they can’t accept 

standard time signal, slave clocks can work depending on it’s precision. 

There are “ADV” and “REV” methods in slave clock. They can chase time automatically, when 

accepting  standard  time  signal,  adjust  fingers  to  standard  time  in  short  time  with  the  shortest 

distance. When it run solely, you can adjust time through keyboard. 

 

 

 

 

 

 

POWER   

CIRCUIT 

CRSTAL   

OSCILLATOR 

 

SINGAL 

  CHIP 

MOVEMENT 

MASTER 

CLOCK 

SIGNAL、POWER CABLE

 

background image

 

12 

4

PANEL INTRODUCTION 

 

 

FRONT PANEL IN BKJ2 MODEL MARINE MASTER-SLAVE CLOCK 

3.    local (slave clock) finger clock 

4.    standard (master clock) finger clock 

5.    standard (master clock) time display window 

6.    local (slave clock) time display window 

7.    master clock power 

8.    slave clock power 

9.    total power 

10. key to adjust master clock time 

11. key to adjust slave clock time   

12. key to stop second 

5

METHOD OF FIXING, SPAN AND ADJUSTING 

1.    fixing 

1

The fixing manner of master clock is hanged or flush type. Fix the clock using fore M4 screws. 

2

  The method of BKJ2/-B2

B6

B9

B12 etc slave clocks are same to master clock. Fix them 

using three or four screws. Refer to drawing when fixing. 

3

BKJ2/-B3(4) slave clock are inlay type. Fix in the commodious plane, refer to the drawing when 

fixing. 

background image

 

13 

2.    the method of connected with exterior 

1

master clock:   

Connect with antenna by Q9 BNC connector plugs, connect with slave clock by four-wire cable. 

“T+” in export of master clock correspond with that in slave clock. “T-” ,

24V

,

VSS

  are same. 

Master  clock  has many  exports,  try  your  best  to  distribute  averagely.  Require:  Connect  exactly 

according to the marks. 

2

parallel connect all slave clocks through four-wire cable. Require: Connected wire must be 

absolutely right, especially power cable must be connected rightly. 

6

OPERATION 

1

First, check the antenna or cable is OK or NOT, and the cable between master clock with slave 

clock is correct or not. 

2

Power cable of AC220V Connect correctly, DC24V also, power switch is set to “OFF”. 

3

Turn on total power switch , at this time neon light should be bright. Two time display windows 

show info. Slave click begin to work. 

4

At this time, if two fingers of master clock and slave clock are not on “12” o’clock, they will run 

there automatically. 

Adjust right key, check the communication of slave clocks.   

7

OPERATION OF KEY AND SWITCH 

1.    key in master clock 

Key in mater clock can be used to adjust time of master clock. 

Press the “HOUR”

  “MIN” key, hour

minute should be adjusted, press once, the amount of 

hour  and  minute  will  increase  or  decrease  one  correspondingly.  Press  the  “+/-”  key,  can 

change the amount of the hour and minute increasing or decreasing. Press the “SEC” key, 

second will reset to work from original position. 

2.    key in slave clock 

Key in slave clock can be used to adjust time of slave clock.. The function of the “HOUR”

“MIN”

  “+/-” key are same to which in master clock.. 

3.    power switch in master clock 

Power supply in master clock is DC24V. It is provided by two pieces of circuits, one comes from 

background image

 

14 

DC24V in alternating current module, the other comes from DC24V provided by storage battery. 

4.    power switch in slave clock   

Power supply in slave clock is same to what in master clock. It is also provided by two pieces of 

circuits,  one  comes  from  DC24V  in  alternating  current  module,  the  other  comes  from  DC24V 

provided by storage battery. 

8

ITEMS AND METHOD IN NATURAL MAINTENANCE 

Keep the equipment in the system dry and clean. 

9

REQUST IN TRANSPORTATION AND STORAGE 

Conveyance manner:      Road or railway   

Note: Convey carefully, not knock. 

require of storage in Short time:      Dampproof and dustproof 

10

REGARDABLE ITEM 

Warning:  Cable  between  equipment  in  the  system  must  be  correct,  especially  power  cable 

must be conformed to be right, otherwise the equipment will be destr

oyed.