background image

 

Published By [Global CS Team in HQ

IMEI84 

 

 

Product 

HHP 

Notice No. 

15-49 

Model 

SM-G920F/G925F 

Notice Date 

26

th

 May, 2015 

Subject 

How to check the X-tal defect regarding S6/S6 Edge No Power issue 

Scope

 

Subsidiary ( Yes ) 

ASC ( Yes ) 

Customer ( No ) 

 

1. Purpose 

- To inform All ASC’s of information regarding h

ow to check the X-tal defect regarding 

  S6/S6 Edge No Power issue

 

2. Background 

- No Power on Galaxy S6 may be caused by X-tal component defect. 

- Follow the below steps to confirm the X-tal defect so that engineers can find the 

  exact root cause of No Power. 

 

3. Introduction 

- Probe the #1 or #3 point of OSC5000 with Oscilloscope and check the signal status 

  of 24MHz frequency. 

- If there is no wave signal from the OSC5000, replace the OSC5000. 

 

 

 

 

Notice 

G925F 

G920F 

background image

 

Published By [Global CS Team in HQ

 

GOOD

 

DEFECT

 

 

 

Normal 24MHz wave signal 

No wave signal 

 

Probe #1 or #3 point 

of OSC5000