Quality Management Rules

  Scope of application 

The following regulations apply to supplies and services of KEIPER incorporated in 

products of the customer or sold as products to the customer; they shall be equally 

binding for both the customer and KEIPER. 

They are applicable even if the customer may have communicated its own diverging 

Quality  Management  Rules.  Customer  Quality  Management  Rules  will  not  be 

recognized,  even  if  KEIPER  does  not  expressly  object  to  them  again  after  their 

receipt at KEIPER.  

  Quality Management System 

The QM system of KEIPER GmbH & Co. KG is certified in accordance with ISO/TS 

16949:2002. 

KEIPER shall be only responsible for the quality of its supplies furnished or services 

provided.  The  responsibility  for  quality  for  customer  furnished  equipment  or 

deliveries shall be at the customer.  

In  case  of  quality  problems,  for  example,  the  customer  shall  be  permitted,  upon 

previous coordination and agreement with KEIPER, to perform a process audit by its 

staff.  

  Environmental Management System 

The  Environmental  Management  System  of  KEIPER  GmbH  &  Co.  KG  is  certified 

according to DIN EN ISO 14001: 2004. 

KEIPER  will  make  the  material  data  required  by  the  End  of  Life  Vehicle  directive 

available to the customer via the International Material Database (IMDS). 

  Advance quality planning 

KEIPER will follow the basic principle of “fault prevention rather than fault detection”. 

A systematic advance quality planning will be conducted.  

1.  Producibility 

KEIPER will check the supplies and services being subject of an order with regard to 

its producibility. Producibility in this context means that the requested product can be 

manufactured  under  series  production  conditions,  particularly  with  respect  to 

requirements such as: 

- Capacities / quantities 

- Deadlines or scheduled times 

- Requirement specification / Performance specification 

- Drawings 

- Specifications 

- Process capabilities for SCs and CCs with Cpk > 1.33  

The  producibility  will  be  checked  for  all  new  and  modified  parts  /  projects.  The 

customer will be notified of problems. 

In  the  case  that  the  customer  is  in charge of the design the customer will provide 

KEIPER with all documents required for reviewing the producibility, such as: 

- Drawings respectively CAD-data of single parts, components and assemblies 

- Design-FMEA including all special characteristics (SCs and CCs) 

- Interface-FMEA to the OEM 

- Specifications 

- Test specifications 

- Listing of all special characteristics (SCs and CCs) 

- Documents containing special customer requirements 

2.  Project plan / milestone plan 

For  the  purpose  of  project  planning  and  project  execution  KEIPER  will  prepare  a 

project or milestone plan. The project plan shall contain the following milestones: 

-  Creation of a Design- and a Process-FMEA 

-  Creation of a control or production control plan (incl. critical characteristics CCs 

   and significant characteristics SCs) 

-  Planning and provision of the test equipment 

-  Manufacture of prototypes (if necessary) 

-  Manufacture of pre-production samples 

-  Determination of the machine or process capability (for CCs and SCs) 

-  Prototype approval by the end customer, being provided by the customer  

-  Performance of initial sampling as per QS 9000 / PPAP or VDA 2 / PPF) 

-  Production start 

-  Start and target dates, resources and actual degree of performance 

KEIPER shall communicate the project status to the customer’s responsible project 

manager in specified intervals. 

3.  Inspection planning and test equipment planning  

Systematic inspection planning and test equipment planning will ensure that for new 

and/or modified products, manufacturing processes, etc: 

- All characteristics of importance to the quality have been registered, 

- The inspection methods and frequencies to be used are appropriate, and 

- The test equipment is correctly designed and available in due time before the  

  start of pilot production. 

The characteristics of importance to the quality shall be included in the drawings and 

specifications. Determination of critical and significant product characteristics which 

have  to  be  considered  specifically  in  the  inspection  planning  and  test  equipment 

planning shall be carried out in coordination with the customer and taking the FMEA 

findings into account. 

 

 

 

 

 

A control plan shall contain the following information: 

- Master data (such as manufacturer, designation, drawing no., technical revision 

  status, obligatory documentation and author / user / date) 

- Inspection characteristic(s) - (at least all CCs and SCs) 

- Test equipment 

- Testing frequency 

- Testing method 

- Type of test (quantitative or qualitative) 

- Sample size or 100% inspection 

- Corrective actions in the event of nonconformities (or individual determination, e.g. 

  in the test instruction) 

The  required  test  equipment  shall  be  manufactured  or  furnished  by  KEIPER  at  its 

sole  responsibility  and  shall  take  economic  and  manufacturing  aspects  into 

consideration. 

4.  Evidence of process capability 

The selection and determination of the characteristics for which evidence of process 

capability  has  to  be  adduced,  shall  be  made  as  early  as  possible.  All  critical  and 

significant  characteristics  for  meeting  the  coordinated  specification  shall  be 

considered. 

-  Preliminary process capability  

 Pp; Ppk > 1,67 

-  Process capability (long-term) 

 Cp; Cpk > 1,33 

  Sample submission procedure 

The  submittal  of  samples  shall  follow  QS  9000  /  PPAP-directive  or  VDA  2  /  PPF 

according to coordination with the customer. Unless otherwise agreed, Submission 

Level 2 shall apply as standard. 

The  following  documents  will  not  be  handed  out.  But  customer  employees  will  be 

able to inspect them on site: 

- Drawings or CAD-data of modules and single parts used, adaptation parts and 

  assembly drawings excepted 

- FMEA documents, interface-FMEAs excepted 

- Control plans 

- Process layout and process-related instructions 

  Labeling, storage and packaging

KEIPER  shall  label  its  goods  in  such  a  way  that  the  product  status  and  the 

inspection status are to be clearly identified at any time, from receipt of the goods 

until dispatching of the goods.  

The goods shall be stored in such a way that they are sufficiently protected against 

loss  /  theft.  The  storage  shall  also  exclude  damages  or  impairment  of  material 

properties due to environmental impact.  

Unless  otherwise  specified  by  the  customer,  KEIPER  shall  be  responsible  for  the 

appropriate packaging for the designated shipping.  

The  cargo  carriers  containing  goods  ready  for  dispatch  shall  as  a  standard  be 

provided  with  a  VDA  label  and  a  QA  certificate.  The  passing  of  the  risk  shall  be 

governed by the conditions stipulated in the contract. 

  Documentation and traceability 

Special archiving documents (DmbA) shall be kept for 15 years after the product has 

been delivered to the customer. This shall enable the specified relevant product or 

process data to be documented and in addition it shall also permit the corresponding 

traceability of the products (in coordination with the customer, if applicable).  

 Production / series monitoring 

By  means  of  regular  monitoring  and  documentation  of  process  parameters  and 

product  characteristics  KEIPER  shall  ensure  a  stable  and  capable  production 

sequence and thus the quality of the manufactured products. For CCs and SCs the 

use of SPC (Statistical Process Control), shall be planned and implemented where 

appropriate and useful. 

  Nonconforming parts

Nonconforming  parts  occurring  in  the  production  of  KEIPER  will  as  a  matter  of 

principle be selected, marked and separated. A mixing with acceptable parts shall be 

excluded to ensure that only contractual items free of deficiencies are delivered.  

KEIPER shall be entitled to supply products that deviate from the specification or the 

test  specification  coordinated  with  the  customer,  if  a deviation permit approved by 

the customer exists.

 

  Incoming inspection at the customer’s plant 

The  customer  shall  inform  KEIPER  of  quality  deviations  immediately  upon  their 

detection  at  incoming  inspection  or  whenever  during  the  course  of  ordinary 

business.  

  Customer complaints 

KEIPER  shall  respond  immediately  to  complaints  relating  to  nonconforming 

contractual  items  concerning  defined  and  coordinated  specifications.  Within  24 

hours, or as individually agreed, KEIPER shall submit to the customer a report (8D-

Report) containing at least the following information: 

 

 

 

 

background image

XXXXXXXXXXXXXX 

xxxxxxx 

XXXXXXXXXX

 

 

 

 

 

 

 

    !

"

 

 

 

- Description of the nonconformance 

- Cause of the nonconformance (if determined within 24 hours) 

- Initiated immediate actions (damage limitation) 

- Remedial actions (elimination of cause immediately after determination of the  

  cause) 

- Preventive actions to avoid repetition 

- Times/dates for actions and persons responsible for their execution 

  Rejection of nonconforming supplies / services 

Prior  to  the  rejection  or  rework  of  nonconforming  supplies  /  services the customer 

and  KEIPER  coordinate  the  actions  to  be  taken  in  order  to  minimize  the  possible 

damages. 

1.   Occurrence / detection of a nonconformance 

In  case  of  detection  of  nonconformance  and  in  consideration  of  assuring  the 

production  and  the  readiness  to  deliver,  the  following  actions as the case may be 

shall be initiated: 

- Return and exchange without delay 

- Separation by KEIPER 

- Rework by KEIPER 

- Replacement by KEIPER 

The costs for activities such as sorting, rework and scrapping will only be borne by 

KEIPER,  if  the  nonconformance  making  necessary  these  activities  are  at  the  sole 

default of KEIPER and if it concerns only the contractually agreed scope of delivery 

at  the  time  of  delivery  of  the  goods  directly  at  the  customer’s  plant,  i.e.  without 

further processing.  

In  principle,  however,  the  absorption  of  the  activities  and  the  costs  associated 

therewith has to be settled between the customer and KEIPER in advance for each 

individual case on the basis of ordinary trade usage.  

2.   Information exchange / examination of defects 

The parties agree to inform each other immediately in case of possible damage risks 

and damages that have already occurred. They agree to work together on measures 

to  avoid  risks  so  that  these  measures  can  be  smoothly  carried  out.  Upon  request 

KEIPER  shall  support  the  customer  in  the  analysis  of  causes  of  nonconformance 

that can be attributed to the product supplied by KEIPER. 

 Secrecy 

Each party assures that it will keep information and knowledge, that it has received 

from its partner– by whatever means – secret and will not make them accessible to 

third  parties  or  use  them  for  other  than  the  intended  purposes  without  the  written 

consent of the partner.  

This obligation shall persist for a period of 3 years following expiration or termination 

of this agreement.