Wiring and Cabling 

Installation Manual 

 
 
Revision history: 
 

REV. DATE  MODIFIER DESCRIPTION 

0 2.4.2008 

AaNi  Created 

A  

 

 

B  

 

 

C  

 

 

D  

 

 

E  

 

 

F    

 

 

 

 

 

 

background image

C102963-0 Page 2 of 2

 

02.04.2008

 

 

 

© The information contained in this document is the sole property of Steerprop Ltd. any reproduction or disclosure in part or whole without written permission is prohibited. 

DOC-1017-1 

 

1 C

ABLING 

 

 

1.1 D

ESIGN AND CABLING WORK

 

The cabling diagrams are purposed for design, selection and installation of the cables 
onboard.  

1.2 S

PECIAL TWISTED PAIR CABLES 

 

The twisted pair cables needed for installation are included in Steerprop scope of 
supply.  (NOTE ! the cables are supplied uncut in manufacturers standard length reels.) 

1.3 W

IRING AND TERMINALS

 

The internal wiring is wired-up to terminal strip or equal. 

All terminals are spring loaded.  

1.4 P

LUGS

 

The Steerprop propulsor and its auxiliary systems like hydraulics are equipped with 
Harting type of plugs. 

1.5 C

ABLE GLANDS

 

There are no cable glands on electronic units except on terminal boxes of propulsor 
and hydraulic power unit for their internal wiring. 

2 W

IRING OR CONNECTION FAILURE

 

Very often the failure or error is caused by  

‰ 

Wire breaks 

‰ 

Short circuits 

‰ 

Loose connections 

‰ 

Insulation wearing 

of wiring or connections. These should first check and repair. 

If the signals have disturbances or noise or level fluctuation, there is conducting or 
radiating disturbances from other systems. 

These can be corrected in the most of cases by checking and repairing of the 
connection of cable screen or pair shield connections specially at connection points. 

Some times helps to move the control cable further away from disturbance source or 
power cable.