background image

Muscle Testing 

(T-0003)

 

Lower Trapezius 

  

 Movie for broad-band (300kbps)

 

 

Check on the radio button that best describes your test results. If the numeric grade is lower 
than 5, click on the NEXT button located on the bottom right hand corner of this page, and 
proceed to the Tape Specification Section.  

 
  

 
 
 

 

Copyright © 2005-2007 Kinesio Taping Association. All Rights Reserved 

KINESIO TAPING

®

English

 | Japanese | Korean

My Account

     

Linder Test 1

Functional Anatomy    

Testing

     Tape Specification     KT Method     Confirmation Testing

 

Patient position: prone, with the shoulder off 
the edge of the table. Abduct the shoulder to 
120 degrees. Externally rotate the shoulder 
so the thumb points to the ceiling. Lift the arm 
to the ceiling.  
 
Examiner pressure: Apply downward 
pressure against the lateral forearm.  
 
Note: the posterior deltoid, teres minor, 
infraspinatus, and elbow extensors must 
stabilize the humerus to the scapula in order 
to use the arm as a lever.  

 

Numeric 

Grade

Percentage 

of normal

Muscular 

Contraction

Functional Level

5

100%

Normal

Full ROM against gravity, sustains position 
with full manual resistance appropriate for age 
and gender

4

75%

Good

Full ROM against gravity, sustains position 
with moderate manual resistance appropriate 
for age and gender

3

50%

Fair

Full ROM against gravity; unable to sustain 
position with minimal resistance applied

2

25%

Poor

Full ROM with gravity eliminated; partial ROM 
against gravity

1

10%

Trace

Evidence of slight muscle action 
(e.g.isometric,twitch,palpation);no joint motion 
produced

0

0%

Zero

No palpable or visible evidence of muscular 
contraction