sl5e105 / 040114

1 / 2

Data

sheet

5 A with PFC

SL5.105

• Input: AC 115V / 230V, DC 210-375 V
• Output: 24...28V / 120 W
• Power Boost up to 144 W
• High overload current, no switch-off
• Quasi-Wide-Range Input
• Robust mechanics and EMV

CUL/CSA-C22.2

EMC and

Low Volt.

UL60950 E137006

UL508 LISTED
IND. CONT. EQ.

No 950-M90

18 WM, 60°C

Directive

CB

scheme

IEC60950

Input

Efficiency, Reliability etc.*

Construction / Mechanics*

Output

* For further information see data sheets „The SilverLine“, 

„SilverLine Family Branches“ and mechanics data sheet

Input voltage

AC100-120/220-240 V (switchable), 47-63 Hz
(85-132 VAC / 176-264 VAC, 210-375 VDC,
also see „Output: Continuous Loading“)

Quasi-Wide-Range Input: With the switch in the 230V position the pow-
er supply unit operates at low and moderate loads (until 3 A) at any in-
put voltage between 95 and 264 V AC (see ’Output’ at the right side).
Note: At DC input, always leave the switch in the 230V position.

Input current

< 2.6 A (switch in 115V position) 
< 1.2 A (switch in 230V position)

• DCin at open output typ. 5 mA (preserves battery sources)

Inrush current

typ. < 15 A  at 264 V AC and cold start

To be fused with a 10A, B-type 'circuit-breaker' switch  based on the usu-
al thermomagn. overload sensing principle (used anyway to fuse the in-
put lines). In addition, the unit contains an internal fuse (not accessible).

Harmonic current 
emissions (PFC)

acc. EN 61000-3-2
Power factor: 0.71 at nominal load

Transient
handling

Transient resistance acc. to VDE 0160 / W2 
(750 V / 1.3 ms), for all load conditions.

Hold-up time

> 27 ms at 196 VAC, 24 V / 5 A 

Efficiency

typ. 88 % 

(230 VAC, 24 V / 5 A)

Losses

typ. 16.3 W

(230 VAC, 24 V / 5 A)

MTBF

400.000 h acc. to Siemensnorm SN 29500 
(24 V/5 A, 230 VAC, T

amb

 = +40 °C)

Life cycle (electrolytics)

The unit exclusively uses longlife electrolytics, 
specified for +105°C (cf. ’The SilverLine’, p.2).

Housing dimensions and Weight
• W x H x D
• Free space for 

ventilation

• Weight

64 mm  x  124 mm  x  102 mm (+ DIN rail)
above/below 25 mm recommended
left/right 15 mm recommended
752g

Design advantages:
• All connection blocks are easy to reach as mounted at the front panel.
• Input and output are strictly apart from each other and so cannot be 

mixed up (input below, output above).

Output voltage

24...28 V DC, adjustable by (covered) front 
panel potentiometer; preset: 24.5 V ± 0.5%
Adjustment range guaranteed

Output noise 
suppression

Radiated EMI values below EN50081-1, even 
when using long, unscreened output cables.

Ambient temperature 
range T

amb

Operation: -10°C...+70°C (>50°C Derating)
Storage: -25°C...+85°C

Derating

typ. 3 W/K  (at T

amb

=+50°C...+70°C)

Voltage regulation

better than 2% Vout over all

Ripple / Noise

< 25 mV

PP

  (20 MHz bandw., 50 

Ω measurem.)

Overvolt. protection

typ. 33 V 

Parallel operation 

yes; current sharing available on request

Power back immunity

34 V

Front panel indicator

Green LED, goes out at V

out

 < 14 V

Continuous loading

(T

amb 

= -10°C...+50°C, 

convection cooling), also 
see diagram overleaf.
For start at T

amb

<0°C and 

low input voltage, please 
contact PULS.

Switch AC/DCin

I

out 

@ 24V I

out 

@ 28V

230V

176-264 V 

5 A (6 A*) 4.3 A (5.1 A*)

95-176 V 

3 A

2.6 A

210-375 V  = 5 A (6 A*) 4.3 A (5.1 A*)
150-210 V  = 3 A

2.6 A

100-150 V  = 2 A

1.7 A

115V

85-132 V 

5 A (6 A*) 4.3 A (5.1 A*)

Output is protected against 
short circuit, open circuit 
and overload 

*

 short-term (< 1 min), at forced cooling even 

continuous

Order information

Order number

Description

SL5.105
SLZ01

Screw mounting set, two needed per unit

background image

Your partner in power supply:

European
Power Supply
Manufacturers 
Association

PULS GmbH

Arabellastraße 15

D-81925 München

Tel.: +49 89 9278-0

www.puls-power.com

Fax: +49 89 9278-199

Data sheet

2 / 2

sl5e105 / 040114

Bayerns Best 50
Czech 100 Best
EuropeÕs 500

Unless otherwise stated, specifications are valid for AC 230V input voltage, +25°C ambient temperature, and 5 min. run-in time. They are subject to change without prior notice.

Start / Overload Behaviour

Further information

Start-up delay

typ. 0.1 s

Rise time

appr. 5-20 ms, depending on load

Overload Behaviour

• Special PULS Over-

load Design 
(s. diagram on the 
right) 

• 20% power boost

– no switch-off, no hiccup if overloaded
– high overload current (up to 1.9 I

Nom

), V

out

 

is gradually reduced with increasing current

– 6 A short-term, at forced cooling even 

continuous

Advantages:
• High short-circuit current, giving large ’start-up window’: unit starts 

reliably even with awkward loads (DC-DC converters, motors).

• No ’sticking’ such as can occur with fold-back characteristics
• Secondary fuses operate reliably

Further information, especially about
• EMC
• Connections
• Safety, Approvals
• Mechanics and Mounting
see page 2 of „The SilverLine“ data sheet.

For detailed dimensions
see SilverLine mechanics data sheet SL2.5/ SL5/ SL10

0

4

8

12

16

20

24

28

32

0

2

4

6

8

10

12

14

Output current Iout [A]

Out

put

 volt

age Vout

 [V

]

T

amb

 =  50°C / 25°C / 0°C

0

10

20

30

40

50

60

70

80

90

100

90

130

170

210

250

290

330

Input voltage VDCin [V]

Hold-up time [ms]

0

10

20

30

40

50

60

70

80

90

100

90

120

150

180

210

240

Input voltage VACin [V]

H

old-

up tim

e [m

s]

2

4

Input voltage ACin [V]

Output current Iout [A]

6

2

4

6

100

200

300

400

100

200

300

400

Input voltage DCin [V]

switch at 115V 

375

210

85

95

132

264

ACin

DCin

switch at
230V 

176

Output current over input voltage

Output characteristic (typ.)

(min., at V

out

=24V)

Hold-up time (min., at V

out

=24V)

ACin

Iout=5A

Iout=3A

Iout=2A

switch pos.

230 V

switch pos.

115 V

Iout=3A

Iout=5A

DCin

Iout=2A

Iout=3A

Iout=5A

 Vout range

74

77

80

83

86

89

1

2

3

4

5

6

7

Output current Iout [A]

Efficiency [%]

85V ACin
115V ACin
132V ACin

78

80

82

84

86

88

90

1

2

3

4

5

6

7

Output current Iout [A]

Efficiency [%]

176V ACin
230V ACin
264V ACin

Efficiency (typ., at V

out

=24V)