1

 

GENERAL............................................................................................................................................... 3

 

1.1

 

L

OCAL 

C

ONTROL 

M

ODE

................................................................................................................... 3

 

1.2

 

P

REPARATION

................................................................................................................................... 3

 

1.3

 

G

ENERAL

.......................................................................................................................................... 3

 

2

 

PROPULSOR CHECKS AT PROPULSOR ROOM BEFORE STARTING................................... 4

 

3

 

PROPULSOR CHECKS AT ENGINE CONTROL ROOM PANEL (ECP) BEFORE 

STARTING ...................................................................................................................................................... 4

 

4

 

PROPULSOR STARTING .................................................................................................................... 5

 

4.1

 

S

TARTING SEQUENCE

....................................................................................................................... 5

 

5

 

PROPULSOR STOPPING .................................................................................................................... 5

 

background image

C102990-0 Page 3 of 5

 

11.04.2008

 

 

 

© The information contained in this document is the sole property of Steerprop Ltd. any reproduction or disclosure in part or whole without written permission is prohibited. 

DOC-1017-1 

 

GENERAL

 

The system starting is beginning from the engine control room. 

1.1 L

OCAL 

C

ONTROL 

M

ODE

 

Check that local control switch on the SCU panel is in “Remote” position. 

1.2 P

REPARATION

 

Before starting the systems, go through the preparation list and make sure that the 
following systems are in starting condition and ready for operation: 

‰ 

Main supplies 

‰ 

Auxiliary supplies 

‰ 

Control system supplies 

‰ 

Back-up supplies 

‰ 

Ship automation systems 

‰ 

Cooling systems 

‰ 

Shafting 

‰ 

Propulsor 

1.3 G

ENERAL

 

Check all pings and cabling and the fastening of the components. 

 

background image

C102990-0 Page 4 of 5

 

11.04.2008

 

 

 

© The information contained in this document is the sole property of Steerprop Ltd. any reproduction or disclosure in part or whole without written permission is prohibited. 

DOC-1017-1 

2 P

ROPULSOR CHECKS AT PROPULSOR ROOM BEFORE 

STARTING

 

CHECK UNIT 

MODULE 

ID 

MARK 

CRITERIA 

ACTION 

IF 

NOT 

Oil temperature 

SAP 

UG 

TG4 

°C 

 

 

Incoming oil to cooler 

HPU  CO1 

TG2 

°C 

 

 

Outgoing oil from cooler 

HPU  CO1 

TG3 

°C 

 

 

Incoming water to oil 

cooler 

HPU CO1   

°C   

 

Lubrication oil pressure 

M2 

 

 

bar 

 

 

Start oil level  

SAP 

UG 

LG2 

Max 

Can be seen at sight glass 

 

Start oil level  

SAP 

UG 

LG1 

Min 

Should be seen at sight glass 

 

Air breather 

SAP 

UG 

 

Clean 

 

Seal oil tank level 

SOT 

 

 

 

Oil level should be between dip 
stick markers 

 

Seal oil tank pressure 

SOT 

 

 

 

 

 

Seal oil tank air shut-off 

valve 

SOT  

 

 

 

 

Oil filter selection valve 

HPU1   

DV 

 

One filter should be selected 

 

Oil filter pressure valve 

HPU1   

SV 

 

Center (closed) 

 

Oil cooler water input 
valve  

SHIP  

 

NO  Open 

 

Oil cooler water output 

valve  

SHIP  

 

NO  Open 

 

3 P

ROPULSOR CHECKS AT ENGINE CONTROL ROOM PANEL 

(ECP)

 BEFORE STARTING

 

FUNCTION TRANSM. 

VALUE 

UNIT 

CRITERIA 

ACTION 

IF 

NOT 

ECR display is working 

 

 

 

 

 

PM starting allowed 

 

 

 

Yes 

 

Lubrication oil pressure upper gear 

BP02 

 

bar 

 

 

Lubrication oil temperature upper gear  BT02 

 

 

 

 

background image

C102990-0 Page 5 of 5

 

11.04.2008

 

 

 

© The information contained in this document is the sole property of Steerprop Ltd. any reproduction or disclosure in part or whole without written permission is prohibited. 

DOC-1017-1 

 

4 P

ROPULSOR 

S

TARTING 

 

Check that system is working and ready for operation. The propulsor is started by ships 
remote control system. 

4.1 S

TARTING SEQUENCE

 

1. Start 

Steerprop 

2.  Wait 15 s 
3.  Start propeller motor drive 

 

CHECK THAT THERE ARE NO ACTIVE ALARMS OR OTHER FAILURE INDICATIONS. 

5 P

ROPULSOR 

S

TOPPING

 

The propulsor is stopped by ships remote control system.