LABORATORIUM ENERGOELEKTRONIKI

SPRAWOZDANIE Z ĆWICZENIA

Temat : Tranzystorowy zasilacz impulsowy .

Skład grupy : 25.12.1996

Dawid Sobieszczański

Andrzej Laskowski

Politechnika Lubelska

Laborarorium Energoelektroniki

w Lublinie

Semestr : VII

Rok. akadem. 1996/97

Nazwisko : Wysocki

Borowiec

Zarajczyk

Imie : Mirosław

Mariusz

Krzysztof

Data wykonania : 12.12.96

Temat : Tranzystorowy zasilacz impulsowy

Ocena :

Schemat układu pomiarowego .

1. Charakterystyki zewnętrzne Uwy = f ( Iwy ) .

Uwe=10 V

Uwe=15 V

d [ % ]

Uwy [ V ]

Iwy [ A ]

Uwy [ V ]

Iwy [ A ]

30

0.8

0.16

1.4

0.4

30

0.6

0.4

1.22

0.6

30

0.5

0.6

1.2

0.8

30

0.4

0.8

1

1.2

30

0.3

1

0.86

1.6

30

-

-

0.8

2.04

50

1.5

0.4

2.6

0.6

50

1.4

0.6

2.4

1

50

1.3

0.8

2.3

1.4

50

1.2

1

2.2

1.8

50

1.1

1.2

2

2.4

50

1.02

1.4

-

-

70

2.3

0.56

3.8

1

70

2.2

0.8

3.6

1.4

70

2.04

1

3.4

1.8

70

2

1.2

3.3

2.2

70

1.8

1.6

3.2

2.6

89

3

0.76

4.92

1.2

89

2.84

1

4.72

1.6

89

2.64

1.4

4.6

2

89

2.5

1.8

4.4

2.4

89

2.4

2.2

4.3

2.8

Charakterystyka Uwy = f ( Iwy ) dla uwe = 10 V . Charakterystyka Uwy = f ( Iwy ) dla Uwe = 15 V .

0x01 graphic

2. Sprawność i charakterystyki Iwe = f ( Iwy ) .

Uwe = 10 V

Uwe = 15 V

d [%]

Iwy

Uwy

Pwy

Iwe

Pwe

η

Iwy

Uwy

Pwy

Iwe

Pwe

η

30

0.16

0.8

0.032

0.02

0.2

0.16

0.4

1.4

0.56

0.1

1.5

0.37

30

0.4

0.6

0.24

0.09

0.9

0.27

0.6

1.22

0.73

0.11

1.65

0.44

30

0.6

0.5

0.3

0.1

1

0.3

0.8

1.2

0.96

0.15

2.25

0.43

30

0.8

0.4

0.32

0.12

1.2

0.27

1.2

1

1.2

0.2

3

0.4

30

1

0.3

0.3

0.15

1.5

0.2

1.6

0.86

1.38

0.28

4.2

0.33

30

-

-

-

-

-

-

2.04

0.8

1.63

0.32

4.8

0.34

50

0.4

1.5

0.6

0.11

1.1

0.54

0.6

2.6

1.56

0.19

2.89

0.27

50

0.6

1.4

0.84

0.18

1.8

0.47

1

2.4

2.4

0.28

4.2

0.57

50

0.8

1.3

1.04

0.21

2.1

0.49

1.4

2.3

3.22

0.38

5.7

0.56

50

1

1.2

1.2

0.26

2.6

0.46

1.8

2.2

3.96

0.49

7.35

0.54

50

1.2

1.1

1.32

0.3

3

0.44

2.4

2

4.8

0.61

9.15

0.52

50

1.4

1.02

1.43

0.35

3.5

0.41

-

-

-

-

-

-

70

0.56

2.3

1.29

0.21

2.1

0.61

1

3.8

3.8

0.38

5.7

0.67

70

0.8

2.2

1.76

0.3

3

0.59

1.4

3.6

5.04

0.5

7.5

0.67

70

1

2.04

2.04

0.36

3.6

0.57

1.8

3.4

6.12

0.65

9.75

0.63

70

1.2

2

2.4

0.44

4.4

0.54

2.2

3.3

7.26

0.79

11.88

0.61

70

1.6

1.8

2.88

0.58

5.8

0.49

2.6

3.2

8.32

0.9

13.5

0.62

89

0.76

3

2.28

0.35

3.5

0.65

1.2

4.92

5.9

0.55

8.25

0.71

89

1

2.84

2.84

0.48

4.8

0.59

1.6

4.72

7.55

0.72

10.8

0.7

89

1.4

2.64

3.7

0.61

6.1

0.61

2

4.6

9.2

0.9

13.5

0.7

89

1.8

2.5

4.5

0.8

8

0.56

2.4

4.4

10.56

1.08

16.2

0.65

89

2.2

2.4

5.28

0.96

9.6

0.55

2.8

4.3

12.04

1.24

18.6

0.65

Charakterystyka Iwe = f ( Iwy ) dla Uwe = 10 V . Charakterystyka Iwe = f ( Iwy ) dla Uwe = 15 V .

0x01 graphic

3. Charakterystyki sterowania Uwy = f (d ) .

Iobc = 1 A

Iobc = 0.5 A

d [%]

Uwy [V]

Uwy [V]

10

1.5

0.1

20

6.3

3

30

11.6

6.5

40

17

10

50

22

11.5

Wnioski :

Badany przez nas w ćwiczeniu układ jest układem obniżającym napięcie .

Charakterystyki wykreślone na podstawie wyników pomiarów mają kształt zbliżony do kształtu charakterystyk teoretycznych .

Sprawność układu w zależności od wartości współczynnika wypełnienia waha się dla napięcia wejściowego równego 10 V od 16% do 65% , natomiast dla napięcia wejściowego równego 15 V , od 27% do 71% . Mogliśmy , więc zaobserwować , że sprawność układu wzrasta wraz ze wzrostem napięcia wejściowego i współczynnika wypełnienia , i jest duża .

Ro

Uwy

Uwe

A2

V2

V1

A1

Zasilacz impulsowy

połączony w układ

mostkowy.